ISG type vertical pipeline pump working conditions
2021/06/02 10:40:54
ISG vertical pipeline pump working conditions: 1. Suction pressure ≤1.0Mpa, or the highest working pressure of the pump system ≤1.6Mpa, that is, pump suction port pressure + pump head ≤1.6Mpa, pump static pressure test pressure is 2.5Mpa, Corside pump valve ISG pipeline centrifugal pump order Please indicate the working pressure of the system. When the working pressure of the pump system is greater than 1.6Mpa, it should be stated separately when ordering. In order to make the pump's flow-through parts and connection parts use cast steel materials. 2. The volume content of solid particles in the conveyed medium does not exceed 0.1% of the unit volume, and the particle size is less than 0.2mm. Note: If the medium used is with fine particles, please specify when ordering, so that wear-resistant mechanical seals can be used. 3. Ambient temperature <40℃, relative humidity <95%. Note: If the medium used is with fine particles, please specify when ordering so that the manufacturer can use wear-resistant mechanical seals. Because your actual flow rate, head, syrup composition, concentration and other parameters are different, please send an email to SAIKEN Pump Industry Email: fan@saikenpumps.com